Skip to content

GT-45 Garniture Tape and Suction Tape

GT-45

The two tapes that run through the rod-forming section — the garniture tape that wraps the paper, and the suction tape that holds the tobacco stream.

This page was machine-translated.

Specifications

TypeGarniture tape and suction tape (rod-forming section)
MaterialWoven polyester/cotton blend; PU-coated variant for high-abrasion sections
DimensionsW 18–45 mm / T 0.6–1.2 mm
Commonly used onHauni (e.g. MK-8000)
Typical service lifeDepends on duty — replace on condition, not on a fixed interval
Typical packing unitRoll, continuous length

What it is

GT-45 covers the two tapes that run through the rod-forming (garniture) section of a cigarette maker. They are different parts doing different jobs:

  • Garniture tape — carries the cigarette paper and the tobacco stream through the forming channel, past the glue application point and through the closing and drying section.
  • Suction tape — runs over the suction chamber and holds the tobacco stream against it while the stream is trimmed to the target weight.

Both are consumables. They run against pulleys, guides and the forming channel at machine speed, and they are replaced on condition rather than repaired.

Where it fits and what it does

The suction tape sits in the suction chamber assembly. It is porous or perforated so that the vacuum can pull the tobacco stream onto it and hold it steady while the trimmer removes the excess. The garniture tape takes over where the trimmed stream is laid onto the paper: it wraps the paper around the rod and carries it through the seam gluing and closing stage. Because both tapes hold the rod while it is still soft, their condition shows up directly in rod weight variation, roundness and seam quality.

How it wears out

Replace on these signs rather than on a fixed calendar interval — actual life depends on machine speed, tobacco blend, glue type and how often the machine is cleaned:

  • Frayed, glazed or thinned edges, or visible damage to the weave.
  • The tape no longer tracks true and drifts towards one pulley side.
  • Rod weight variation or roundness drifting with no other cause.
  • Seam marks, paper creases or glue squeeze-out appearing on the rod surface.
  • Tobacco dust packed under the tape or worked into the weave.
  • On the suction tape: the stream slips or pulses instead of being held steady.

What to check when selecting

  • Width and thickness must suit the forming channel — the tape should sit in the channel without rubbing its sides.
  • Material: a polyester/cotton weave is the usual general-purpose choice; synthetic and PU-coated variants are used where abrasion or moisture is the dominant wear mechanism.
  • Joint type: endless versus spliced. A splice is both a common failure point and a possible source of periodic marks on the rod.
  • Surface and coating: friction against the paper and the channel, and whether the coating survives the cleaning agents in use.
  • For the suction tape: the perforation or porosity pattern has to match the suction chamber it runs over.

Fitting notes

Relieve the tension before removing the old tape and keep it as a length reference. Clean the channel, pulleys and guides before fitting the new tape — dust packed underneath shortens its life and marks the rod. Check pulley alignment and crowning: most tracking trouble is geometry, not tape. Fit without creases and without twisting, run in at low speed, then re-tension once the tape has settled. On a spliced tape, keep the joint away from the forming point.

Dimensions and fitment

To confirm width, thickness and joint type for your machine, send the machine model, the measurements taken off the old tape and a photo of any marking to sales@cigmatic.com.

Related

Request a quote

Tell us the model and what you need. We reply from the same mailbox you write to.

Sending this form is not connected yet. Until it is live, email us directly: sales@cigmatic.com

Only used to reply to you — never published, never shared.